SDS Studio™
Solvents

Isopropanol (CAS 67-63-0) – CLP classification and SDS guide

Isopropanol (propan-2-ol) is classified under CLP as Flam. Liq. 2, H225; Eye Irrit. 2, H319; STOT SE 3, H336 (Annex VI harmonised entry). Disinfectants, cleaners and inks containing it need an SDS that reflects this classification.

Identifiers

CAS number67-63-0
EC number200-661-7
CLP Index number603-117-00-0
FormulaC3H8O
Synonymspropan-2-ol, isopropyl alcohol, IPA, 2-propanol

Classification

Harmonised classification (CLP Annex VI): Flam. Liq. 2, H225; STOT SE 3, H336; Eye Irrit. 2, H319

Label elements

GHS02 pictogram
GHS02
GHS07 pictogram
GHS07

Signal word: Danger

Hazard statements

  • H225 Highly flammable liquid and vapour.
  • H336 May cause drowsiness or dizziness.
  • H319 Causes serious eye irritation.

Typical precautionary statements

  • P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
  • P233 Keep container tightly closed.
  • P240 Ground and bond container and receiving equipment.
  • P241 Use explosion-proof [electrical/ventilating/lighting/…] equipment.
  • P261 Avoid breathing dust/fume/gas/mist/vapours/ spray.
  • P280 Wear protective gloves/protective clothing/eye protection/face protection.
  • P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
  • P403+P235 Store in a well-ventilated place. Keep cool.

Occupational exposure limits

CountryLimit (8 h)Short-termSource
HU200 ppm / 500 mg/m³400 ppm / 1000 mg/m³5/2020. (II. 6.) ITM rendelet, 1. melléklet
DE200 ml/m³ / 500 mg/m³Excursion factor 2(II)TRGS 900 (as amended 5 June 2026)

What to watch in your SDS

  • Section 8: the Hungarian limit (5/2020. ITM, Annex 1) carries the skin notation „b”: dermal uptake contributes to exposure, so §8.2 skin protection must reflect it.\n- Section 2: check the generic concentration limits for H319 and H336 (10% and 20%) against the mixture composition.\n- Section 8: list the national exposure limit of every target country.\n- Section 14: isopropanol is UN 1219 (ISOPROPANOL), class 3, packing group II.\n- Section 15: disinfectants with isopropanol fall under the Biocidal Products Regulation (EU) 528/2012.

Sample SDS preview

SAMPLE – not valid for supply

This full 16-section sample SDS was generated in SDS Studio™ for the substance, with a fictitious supplier. It shows the format your own SDS gets. Download the sample PDF or create the SDS for your own product.

Need an SDS for a product containing Isopropanol?

Build a complete EU SDS with CLP classification in about 10 minutes, in up to 28 languages. Your first project is free, no card needed.

Make it your own →

Frequently asked questions

How is Isopropanol classified under CLP?

Harmonised classification (CLP Annex VI): Flam. Liq. 2, H225; STOT SE 3, H336; Eye Irrit. 2, H319.

What H-statements apply to Isopropanol?

H225 (Highly flammable liquid and vapour.), H336 (May cause drowsiness or dizziness.), H319 (Causes serious eye irritation.).

What should an SDS for a mixture with Isopropanol include?

Classify the mixture by its own data and concentration limits, list Isopropanol in Section 3 with CAS 67-63-0, add the national exposure limits of every target country in Section 8, and check transport and national lists in Sections 14 and 15.

Data from the ECHA C&L Inventory. Information only; it does not replace the SDS of your supplier. Last verified: 2026-11-12.