Oxygen (CAS 7782-44-7) – CLP classification and SDS guide

Oxygen is classified under CLP as Ox. Gas 1, H270; Press. Gas, null (Annex VI harmonised entry). Any mixture containing it needs an SDS that reflects this classification.

Identifiers

CAS number7782-44-7
EC number231-956-9
CLP Index number008-001-00-8
FormulaO2
Synonymsdioxygen

Classification

Harmonised classification (CLP Annex VI): Ox. Gas 1, H270; Press. Gas, null

Label elements

GHS03 pictogram
GHS03
GHS04 pictogram
GHS04

Signal word: Danger

Hazard statements

  • H270 May cause or intensify fire; oxidiser.
  • H280 Contains gas under pressure; may explode if heated.

Typical precautionary statements

  • P220 Keep away from clothing and other combustible materials.
  • P244 Keep valves and fittings free from oil and grease.
  • P370+P376 In case of fire: Stop leak if safe to do so.
  • P403 Store in a well-ventilated place.
  • P410+P403 Protect from sunlight. Store in a well-ventilated place.

What to watch in your SDS

  • Section 2: Ox. Gas 1 (H270); H280 or H281 is added by the supplier depending on how the gas is supplied.\n- Section 7: keep valves and fittings free from oil and grease.\n- Section 14: UN 1072 (OXYGEN, COMPRESSED), class 2.2 (5.1).

Need an SDS for a product containing Oxygen?

Build a complete EU SDS with CLP classification in about 10 minutes, in up to 28 languages. Your first project is free, no card needed.

Make it your own →

Frequently asked questions

How is Oxygen classified under CLP?

Harmonised classification (CLP Annex VI): Ox. Gas 1, H270; Press. Gas, null.

What H-statements apply to Oxygen?

H270 (May cause or intensify fire; oxidiser.), H280 (Contains gas under pressure; may explode if heated.).

What should an SDS for a mixture with Oxygen include?

Classify the mixture by its own data and concentration limits, list Oxygen in Section 3 with CAS 7782-44-7, add the national exposure limits of every target country in Section 8, and check transport and national lists in Sections 14 and 15.