Key takeaways
- A PCN is required under CLP Annex VIII for mixtures classified for health or physical hazards placed on the EU market.
- Every notified mixture needs a UFI printed on the label.
- The notification is an IUCLID .i6z dossier submitted to ECHA, in the languages of the target countries.
- The dossier file alone is not a submission: it must be validated and submitted to ECHA.
- SDS Studio™ builds the dossier from your SDS data for €59 + VAT, free with a subscription.
Who must submit a PCN?
Importers and downstream users who place a mixture classified for health or physical hazards on the EU market must notify the appointed bodies (poison centres) of the Member States where the product is sold. Notification goes through ECHA, which forwards it to the countries you select.
What data do you need?
- Submitting company with its ECHA Legal Entity UUID.
- Product name, UFI and EuPCS product category.
- Composition: every component with identifiers and concentration ranges that cover 100%.
- Classification, label elements and Section 11 toxicological information.
- pH, physical state, colour, packaging and target countries.
Preparing the dossier step by step
- Open the PCN moduleStart it from a finished SDS Studio™ project; composition, classification and Section 11 are prefilled.
- Check UFI and compositionGenerate or enter the UFI. The software checks coverage, concentration ranges and Annex VIII tolerances and suggests corrections, for example adding water as the remaining component.
- Choose target countriesToxicological text is prepared in the languages of the selected countries.
- Generate the .i6z dossierThe IUCLID file is created and locked as a version, so the issued dossier is never rewritten.
Path A: submit directly through ECHA S2S
Save your own ECHA S2S key for your submitting company. SDS Studio™ tests the connection, then sends the dossier to the ECHA test environment for validation. After a successful validation you confirm the production submission, and the software shows the submission result.
Path B: manual upload in IUCLID Cloud
- ECHA Submission PortalSign in to ECHA and open the ECHA Submission Portal.
- Create a dossier in IUCLID CloudChoose this option on the portal start page.
- IUCLID 6 Access serviceOpen IUCLID 6 with the Access service button.
- UploadImport the downloaded .i6z file, then click Open.
- ValidationRun Validation manually; ECHA does not validate automatically.
- SubmissionIf validation passes, go back and submit the dossier.
After submission
Keep the submission number. Some Member States charge a fee or ask for extra information after submission. SDS Studio™ shows these steps for information; they are not legal advice.
When the composition or classification changes, submit an update with the same UFI or a new one, depending on the change.
Frequently asked questions
Is downloading the .i6z file enough?
No. The file must be validated and submitted to ECHA, either through S2S or manually in IUCLID Cloud.
How much does a PCN cost in SDS Studio™?
€59 + VAT per notification on pay-per-use; free with a Pro, Business or Infinite subscription. Correction versions are free.
Do I need a new UFI for every product?
Each mixture composition needs its own UFI. Products with the same composition can share one.



